ISO 3452-3 Type 1 reference block

ISO 3452-3 Type 1 reference block
ISO 3452-3 Type 1 reference block ISO 3452-3 Type 1 reference block

Imagem Grande :  ISO 3452-3 Type 1 reference block

Detalhes do produto:
Lugar de origem: China
Marca: HUATEC
Certificação: ISO 3452-3
Número do modelo: Bloco de penetração tipo I ISO 3452-3

ISO 3452-3 Type 1 reference block

descrição
Nome: Bloco de penetração tipo I ISO 3452-3 usar: Usado para determinar o nível de sensibilidade da linha de produtos penetrantes
Aplicativo: Testes DNT da indústria Garantia: 12 meses
Destacar:

ISO 3452-3 Type 1 reference block

,

NDT reference block for testing

,

Type 1 penetrant testing block

ISO 3452-3 Type 1 reference block

Twin NiCr Sensitivity Panels,NiCr Twin Cracked Penetrant Test Panels

ISO 3452-1 Type 1 Test Panel

The NiCr Twin Cracked Penetrant Test Panels are used for comparing and evaluating sensitivity and performance of Dye Penetrants.

They are available in 10, 20, 30 and 50 microns (0.0004, 0.0008, 0.0012, 0.002 inch) flaw depth.

Each set consists of a pair of identical panels marked A and B with manufacturer`s certification and crack photograph.

These panels are made by plating hard Nickel Chromium alloy on a 2mm thick brass substrate and stressing the panel in tension. The hard NiCr is brittle in comparison to the brass substrate so that the cracks created in the plated layer are limited to the thickness of the layer. The panel is then cut in half perpendicular to the direction of the cracks thus creating a matching pair of virtually identical cracks of controlled depth.

NiCr Panels are used to compare new and used penetrants and can also be used for comparing performance of different penetrant materials or different processing techniques.

Sensitivity* (unofficial)

 

 

 

 

Fluorescent Penetrant Sensitivity Levels are established by the USAF Laboratory under highly controlled conditions. Sensitivity testing is not something the penetrant manufacturer or user can do. What you can do is compare samples using appropriate NiCr Cracked Panels.

 

 

Crack Depth

 

Level

50 μm

1, 2, 3, 4

30 μm

2, 3, 4

20 μm

3, 4

10 μm

4

Guaranteed to be equivalent to both Sherwin and Magnaflux supplied panels.

Specifications Compliance: ASTM E1417, AMS 2647D, ISO 3452-3, JIS Z 2343-3ISO 3452-3 Type 1 reference block 0

 